This article explains the Hybird product naming system and how to decode model numbers.
RCBO naming
Format: HY-RCBO-B[amps]C[poles]P[sensitivity]A
Code segment Meaning HY-RCBO Hybird RCBO (combined overcurrent + earth leakage protection) B[amps] Breaker rated current in amps (e.g., B16 = 16A, B32 = 32A) C Trip curve (C = standard stock, B curve available by request) [poles]P Pole configuration (2P = single-phase, 4P = three-phase) [sensitivity]A Leakage sensitivity (3A = 30 mA standard, XA = 300 mA)
Examples:
HY-RCBO-B16C2P3A - 16A, C curve, 2-pole, 30 mA sensitivity
HY-RCBO-B32C4P3A - 32A, C curve, 4-pole, 30 mA sensitivity
HY-RCBO-B50C4PXA - 50A, C curve, 4-pole, 300 mA sensitivity
300 mA variants are available in 32A, 50A, and 63A ratings (4-pole only). B curve is available by request with approximately 4 weeks lead time.
MCB naming
Format: HY-MCB-M[amps]C[poles]P
Code segment Meaning HY-MCB Hybird MCB (overcurrent protection only) M[amps] Rated current in amps C Trip curve (C = standard, B curve available by request) [poles]P Pole configuration (2P or 4P)
Examples:
HY-MCB-M16C2P - 16A, C curve, 2-pole
HY-MCB-M63C4P - 63A, C curve, 4-pole
RCD naming
Format: HY-RCD-R[amps][poles]P[sensitivity]B
Code segment Meaning HY-RCD Hybird RCD (earth leakage protection only) R[amps] Rated current in amps [poles]P Pole configuration (2P or 4P) [sensitivity]B Sensitivity and type (3B = 30 mA Type B). Also available in 100 mA.
Examples:
HY-RCD-R252P3B - 25A, 2-pole, 30 mA Type B
HY-RCD-R634P3B - 63A, 4-pole, 30 mA Type B
Controller and accessories
Product code EAN Description BASE-LTE-LAN 5744007953390 Hybird Edge Controller (standard) BASE-LTE-LAN-O 5744007953406 Hybird Edge Controller with outdoor enclosure (+35 DKK) PSU 5744007953413 Power supply unit (230V AC to 24V DC) UPS 5744007953420 Uninterruptible power supply (3.7V / 20Ah Li-Polymer)
Old naming
Earlier documentation used different model designations. If you encounter these, here is the mapping:
Old designation Current equivalent HY-RCBO HY-RCBO-B[amps]C[poles]P[sensitivity]A HY-MCB HY-MCB-M[amps]C[poles]P HY-RCD HY-RCD-R[amps][poles]P[sensitivity]B CLAN / BASE-LTE-LAN BASE-LTE-LAN (Hybird Edge Controller) CLTE / BASE-LTE-LAN-O BASE-LTE-LAN-O (Hybird Edge Controller with outdoor enclosure)
Curve types
C curve - standard stock. Suitable for moderate inrush loads (motors, fluorescent lighting, most commercial applications).
B curve - available by request, approximately 4 weeks lead time. Standard for resistive loads (heating, lighting). Higher cost.